Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

SolarPlus has specific tools for modelling offOff-grid or systems (aka SAPS systems), namely:

...

Generator run time and fuel cost calculations

...

Detailed load profile calculator

...

AC-coupled and DC-coupled battery charge modelling

...

Off-grid specific proposal template

...

Table of Contents
minLevel1
maxLevel2
outlinefalse
typelist
printablefalse

Off-grid systems follow the same system design approach as grid-connect, with some minor changes.

Table of Contents

...

Generator Run time and fuel cost calculations

  1. On the Energy page, under Energy Costs, select ‘Off-grid’.

  2. You will then be prompted to choose between:

    1. Compare with 100% Generator. Choose this option if the client is currently running a generator to supply their loads.

    2. Compare with Grid Connection. Choose this option if the client currently has no power and is comparing the cost of connecting to the grid against an off-grid solar and battery system.

...

  • SolarPlus does not currently check the load continuously and surge demand against the ratings of your selected inverter/charger. Please check this yourself for now.

  • Please disregard the graphs generated on the Energy Page in V4 - they cannot accurately reflect seasonal variations in load.

  • To include in the handover manual,

    • in your web browser menu, select File > Print

    • set Zoom to 30%, and orientation to landscape

    • save as PDF

    • upload PDF on Commissioning Page

Grid Configuration

On the System Designer page, on the right under Grid Configuration, select Off-grid. This will ensure that the correct handover manual template and SLD structure is used.

DC-Coupled MPPT charge controllers

DC-coupled charge controllers are managed in SolarPlus in the same way as PV Inverters and can be selected under the Inverter section on the left-hand side.

Off-grid System Performance

...

Modelling

The Design Review page is similar to grid-connect systems, with the addition of a generator supply in place of the grid.

...

You can simplify the graph by de-selecting unwanted parameters, and just showing specific ones, such as Genset Supply and Battery Charge.

...

Off-grid proposal template

When your design and quote are finalised, be sure to select the Off-grid proposal template to send to your customer. This can be customised to suit your specific needs.

Off-grid SLDs and System Handover Manuals

On the System Designer page, on the right under Grid Configuration, select Off-grid. This will ensure that the correct handover manual template and SLD structure is used.